B. Connection for Power-- off-to-Unlock type:
-
+12V
LK - (GND)
LK+(COM)
+
N.O.
12V 300mA
EB+
EB -
Jumper set to 2-3 position
12
set to Normally Closed on the
3
Unlock Relay mode on DT software.
2. Additional power supply
DIPS
ON
1 2 3 4 5 6
DIPS-5: set to on,
unlocking time is 5 seconds.
When the electronic lock is over 12 Vdc, additional power supply for the lock is needed.
The power supply for the lock must be less than 48Vdc 1.5A.
The Jumper must be removed when using additional power supply. The default is set for Power-to-Unlock
type(Normally open), if use Power-off-to-Unlock type, change the Unlock Relay mode to Normally closed on
the Parameter tab of DT CONFIG software.
If different unlocking time is needed to be configured, please use the DT CONFIG software to change the setting
on the Parameter tab(see the program section).
C. Connection for Power-to-Unlock type:
Note:
Cut off this line when using
additional power supply
+
-
+12V
DIPS
+
LK - (GND)
LK+(COM)
N.O.
1 2 3 4 5 6
-
EB+
EB -
Remove the Jumper
1
set to Normally Open on the
2
3
Unlock Relay mode.(default)
ON
DIPS-5: default set to off,
unlocking time is 1 second.
(In most cases, 1 second is
work for Power-to-Unlock type)
D. Connection for Power-- off-to-Unlock type:
Note:
Cut off this line when using
additional power supply
+ -
+
-
Remove the Jumper
set to Normally Closed on the
+12V
DIPS
LK - (GND)
LK+(COM)
N.O.EB+
ON
1 2 3 4 5 6
EB -
DIPS-5: set to on,
1
unlocking time is 5 seconds.
2
3
Unlock Relay mode on DT software.
DT - System - Technical Guide 10