Si2400
Rev. 1.3 53
Reset settings = 0001_0000
b
(0x10)
S13 (MF3). Modem Functions 3
BitD7D6D5D4D3D2D1D0
Name
JID BTID OFHE OFHD ONHD CIDB CIDU PCM
Type R/W R/W R/W R/W R/W R/W R/W R/W
Bit Name Function
7JIDJapan Caller ID.
0 = Disable.
1 = Enable.
6BTID
BT Caller ID Wetting Pulse.
0=Enable.
1=Disable.
5OFHE
Enable Off-Hook.
Enable off hook in current limit mode for overcurrent detection.
0 = Disable.
1 = Enable.
4OFHD
Off-Hook Intrusion Detect Method.
0=Absolute.
1 = Differential.
3ONHDOn-Hook Intrusion Detect Method.
0=Absolute.
1 = Differential.
2CIDB
British Telecom Caller ID Decode.
0 = Disable.
1 = Enable.
1CIDU
BellCore Caller ID Decode.
0 = Disable.
1 = Enable.
0PCM
PCM Data Mode.
DTE rate must be 228613, and flow control must be used.
0 = Disable.
1 = Enable.